Skip Navigation


JAC Advance Access originally published online on April 27, 2009
Journal of Antimicrobial Chemotherapy 2009 64(1):94-100; doi:10.1093/jac/dkp145
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplementary Data
Right arrow All Versions of this Article:
64/1/94    most recent
dkp145v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Kokai-Kun, J. F.
Right arrow Articles by Mond, J. J.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kokai-Kun, J. F.
Right arrow Articles by Mond, J. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Original research

Lysostaphin eradicates established Staphylococcus aureus biofilms in jugular vein catheterized mice

John F. Kokai-Kun*, Tanya Chanturiya{dagger} and James J. Mond

Biosynexus Incorporated, 9298 Gaither Rd, Gaithersburg, MD 20877, USA

Received 5 January 2009; returned 16 March 2009; revised 20 March 2009; accepted 31 March 2009


* Corresponding author. Tel: +1-301-987-1172; Fax: +1-301-944-2141; E-mail: johnkun{at}biosynexus.com

Objectives: Staphylococcus aureus infections associated with indwelling devices can be very difficult to treat due to the recalcitrant nature of bacterial biofilms to conventional antibiotics. Lysostaphin has been shown to clear S. aureus biofilms in vitro, and in this study we determined whether lysostaphin could also eradicate established S. aureus biofilms on implanted jugular vein catheters in mice.

Methods: Jugular vein catheterized mice (four to six per group) challenged with S. aureus developed multiorgan infection and biofilm infections on the catheters. The infected mice with established biofilms received various doses of recombinant lysostaphin through the catheters, administered up to three times daily for up to 4 days. Some mice also received lysostaphin combined with nafcillin. Following treatment, mice were sacrificed and cfu on the catheter and in the liver and heart were determined. In another set of experiments, implanted jugular vein catheters in mice were pre-instilled with lysostaphin to determine whether this pre-treatment would protect the mice from biofilm infection.

Results and conclusions: Lysostaphin administered at 15 mg/kg in combination with 50 mg/kg nafcillin three times per day for 4 days eradicated established S. aureus, including methicillin-resistant S. aureus, biofilms from implanted catheters and sterilized heart and liver infections of S. aureus-infected mice. Furthermore, a single pre-instillation of 10 mg/kg lysostaphin in catheters completely protected catheterized mice from a subsequent biofilm infection. These results demonstrate that lysostaphin is an effective treatment as well as prophylaxis for S. aureus biofilms on indwelling catheters.

Keywords: MRSA , nafcillin , heart , liver , dosing regimen , pre-instillation


{dagger} Present address: National Institutes of Health, NIDDK, Building 31, 31 Center Dr., Bethesda, MD 20892, USA.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.