Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Holt, H. A.
Right arrow Articles by MacGowan, A. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Holt, H. A.
Right arrow Articles by MacGowan, A. P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Journal of Antimicrobial Chemotherapy (1994) 34, 747-754
© 1994 The British Society for Antimicrobial Chemotherapy


research-article

An evaluation of three new immunoassays for determination of serum gentamicin concentrations

H. A. Holt, L. O. White, K. A. Bedford, K. E. Bowker, D. S. Reeves and A. P. MacGowan

Regional Antimicrobial Reference Laboratory, Department of Medical Microbiology, Southmead Health Services NHS Trust Westbury-on-Trym, Bristol BS10 5NB, UK

Received 13 April 1994; accepted 7 July 1994


Three new immunoassays for determination of serum gentamicin concentration were assessed: a latex agglutination assay (Technicon), an enzyme immunoassay (EMIT 2000) and a multi-layer thin-film immunoassay (Opus). All three were easy to use, had good within- and between-assay reproducibility, good reliability and acceptable linearity. The standard curve stability was shortest with the latex agglutination assay and longest with the thin-film. The thin-film assay calibrators gave approximately double the expected concentration when assayed by polarisation fluoroimmunoassay but this did not effect the assay's performance. When compared with the polarisation fluoroimmunoassay results of patient samples, all three methods gave an excellent correlation. The technical aspects of these three methods make them acceptable for clinical use.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.